Architecture

Planning with hemp blocks: construction methods, values and approvals.


λ 0.071

W/(mK) thermal conductivity, from block 9 upwards

R 5.07

m²K/W at 50 % humidity, block 36

µ 2.8

water vapour diffusion resistance factor

α 0.85

sound absorption coefficient

Hemp blocks in the design

IsoHemp hemp blocks are made of hemp shives, lime and water and are produced in Belgium. They come in eight thicknesses from 7.5 to 36 cm.

The hemp block carries itself but takes no further loads. Loads are always carried by a separate structure, for example of reinforced concrete, steel, timber or solid masonry. The block forms the envelope, the infill or the partition.

The blocks are laid in thin-bed with IsoHemp adhesive mortar. Interior and exterior plasters must suit the moisture-regulating properties of the block.

Construction methods

Reinforced concrete with Hempro

Columns are cast in P blocks and beams in U blocks, with the blocks acting as permanent formwork. This creates a 30 or 36 cm hemp block wall with an integrated structure.

The Hempro system

Timber frame

The light structure lacks thermal mass. Used on the inside, the hemp block adds this mass to the wall; on the outside it provides the substrate for mineral plasters. Services are easy to install.

Timber post and beam

The block fills the bays between the load-bearing members as solid, diffusion-open infill. Large spans and an exposed timber structure remain possible.

Cross-laminated timber (CLT)

The CLT panels form the structure; the hemp block adds insulation and thermal mass. Non-load-bearing interior walls and partitions of hemp block also make routing services easier.

Steel frame

Steel conducts heat well. U blocks therefore encase columns and beams, with hemp block masonry between them. Connections use brackets or angles as specified by the structural design.

Multi-storey buildings

In residential complexes and office buildings, the block forms a continuous envelope around the structure. In Germany, the approval limits infill masonry to building heights of up to 18 m.

Internal insulation in existing buildings

The block is placed in front of the existing wall and the gap of at least 3 cm is filled with HL Mix. Also suitable for timber-framed and listed buildings.

External insulation in existing buildings

The blocks stand on the foundation or existing masonry and are mechanically fixed to the wall. Finishes include mineral plaster, cladding, brick or clinker.

Partitions

Non-load-bearing interior walls for residential and commercial buildings. The sound reduction index is 37 to 44 dB depending on thickness (simulated, plastered).

Project example: hemp blocks and clay bricks in an onion store

Onions release heat and moisture in storage, yet temperature and humidity should stay as even as possible. For a hall concept measuring 27 x 37 m and 9 m high, we therefore combined two blocks: the hemp block on the outside insulates, the clay brick on the inside carries loads and stores heat.

The clay plaster forms the airtight layer on the inside while the wall stays diffusion-open. At a wall height of 9 m, a timber frame provides bracing. The slow-reacting envelope can support cooling and dehumidification but does not replace the plant.

The clay-hemp wall on lehm-laden.de

Layer from outside to insideThickness
Lime plaster20 mm
IsoHemp hemp block250 mm
GIMA clay brick240 mm
conluto terra coarse clay plaster15 mm
Value of the calculated build-upValue
U-value0,25 W/(m²K)
Total heat storage, of which on the room side797 / 633 kJ/(m²K)
Amplitude damping> 100
Total thickness and mass52,5 cm / 522 kg/m²
Condensation in the calculated casenone

A project-specific model calculation puts the possible advantage over a standard solution at around €11,000 per year. It is based on assumptions about energy, operation and service life and is not a general promise of savings. All values apply only to the calculated build-up (as of March 2026). Block 25 is not covered by the German approval. Each building project requires its own verification.

Internal insulation in timber framing: hemp block or wood fibre

We calculated two approaches for a timber-framed wall, each from outside to inside. Variant 2 insulates about twice as well in the infill panel and stays well below the Glaser condensation limit there. The weak point of all variants is the oak beam.

Variant 1: clay infill with wood fibre

Outside Hessler HP 9 L with Beeckosil paint, light clay bricks in the panel, 2.5 cm clay base plaster, 6 or 8 cm Gutex Thermoroom, 2 cm clay plaster.

Variant 2: hemp block in the panel and inner leaf

Outside Saint-Astier Kalamua without paint, 12 cm hemp block in the panel, 4 cm HL Mix, inner leaf of 12, 15 or 20 cm hemp block, 2 cm clay plaster.

ValueThermoroom 60 mmThermoroom 80 mmHemp block 12 + 12Hemp block 12 + 15Hemp block 12 + 20
Wall thickness (cm)25,527,5323540
U-value, panel, W/(m²K)0,490,400,240,220,19
Overall U-value with 1/6 oak, W/(m²K)0,480,390,260,230,20
Weight per area, kg/m²275278154163179
Effective room-side storage κi, kJ/(m²K)3838424242
Decrement factor f0,230,210,110,070,04
Phase shift, h10,111,016,518,421,5
Condensation in the panel (Glaser), kg/m²1,8–2,91,7–2,5≤ 0,11≤ 0,020
Condensation at the oak beam (Glaser), kg/m²1,5–2,11,5–2,11,1–1,41,1–1,31,0–1,2
Beam dries out fully in summeryesyesin 2 of 4 casesnono
  • Position of the insulation: in variant 1 a thin insulation layer sits in front of the cold clay infill, and condensation forms behind it in winter. In variant 2 the whole wall insulates.
  • Heat storage: variant 1 is heavier, but its mass lies behind the insulation and has little effect on the room. Thicker hemp blocks do not increase room-side storage because the daily cycle only reaches the inner centimetres.
  • Summer heat protection: with hemp block, a much smaller share of the daily heat fluctuation reaches the inside, and it does so 5 to 11 hours later.
  • Space: the hemp block wall is 4.5 to 14.5 cm thicker. This needs weighing up in tight rooms.

Important for planning: at the oak beam, all variants are at or above the Glaser limit of 1.0 kg/m². Glaser accounts for neither capillary moisture distribution nor driving rain. Each variant therefore needs a site-specific hygrothermal simulation to WTA before it is built. Kalamua is water-repellent, so with exposed timber framing the joints between plaster and beam must also be considered.

Calculated values: U-value to DIN EN ISO 6946, storage and heat protection to ISO 13786, condensation by the Glaser method (DIN 4108-3). Overall value with 10 cm wide oak beams at 60 cm centres. The values apply only to these build-ups and do not replace project-specific verification.

Thermal resistance of typical wall build-ups

Construction methodBuild-upR (m²K/W)
Hempro (reinforced concrete)Block 304,43
Hempro (reinforced concrete)Block 365,27
Hempro (reinforced concrete)Block 36 + block 126,96
Timber framewithout hemp block5,3
Timber frame+ block 96,4
Timber frame+ block 126,8
Timber frame+ block 157,3
Post and beamBlock 365,4
Post and beamBlock 20 + block 206,0
Post and beamBlock 36 + block 157,5
Internal insulation with 3 cm HL MixBlock 91,86
Internal insulation with 3 cm HL MixBlock 122,28
Internal insulation with 3 cm HL MixBlock 152,71
Internal insulation with 3 cm HL MixBlock 203,41
Internal insulation with 3 cm HL MixBlock 254,11

Manufacturer data based on simulations. Hempro U-values: 0.226 (block 30), 0.19 (block 36), 0.144 W/(m²K) (block 36 + 12). In timber frame construction, damping rises from 27.9 without hemp block to over 100 with hemp block.

Approval and verification in Germany

  • General building approval and construction type permit Z-17.25-1331 is valid until 20.01.2031. It covers infill masonry of 36 cm hemp blocks with IsoHemp adhesive mortar.
  • Limits of use: building height up to 18 m, wind zones I to III inland.
  • Fire resistance under the approval: F30-B as non-load-bearing masonry up to 4 m high, adjacent members at least fire-retardant. The data sheet values in the table below do not replace this verification.
  • Sound insulation: calculated verification to DIN 4109-2 with Rw 43 dB (36 cm, plastered on one or both sides, at least 150 kg/m²).
  • Design: the infill area is verified with a minimum weight of 270 kg/m³, the substructure with an upper limit of 500 kg/m³ without plaster.
  • Other thicknesses and uses are not covered by this approval. Clarify them early in the project with the structural engineer and the building authority.

What matters in the details

  • Base: the first course is protected from moisture, with a damp-proof membrane and a recommended start at least 20 cm above ground.
  • Bond: overlap of about half a block length, at least 25 cm at the wall edges.
  • Anchoring: force-locked and shown in the detailed design. At the wall sides in at least every second bed joint, spacing no more than 40 cm.
  • Openings: lintels carry only the masonry above, no floor loads. Bearing at least 20 cm, and at least 30 cm per side for openings over 160 cm.
  • Weather: external walls need a suitable plaster against driving rain and splash water. Masonry may remain unfinished for no more than 3 months, or under a finished roof for no more than 1 year with at most 1 winter.
  • Hempro: maximum filling height of 50 cm per hour when pouring concrete.

Installation

Technical values

Value79121520253036Unit
Thickness7590120150200250300360mm
Length x height600 x 300600 x 300600 x 300600 x 300600 x 300600 x 300600 x 200600 x 200mm
Blocks per m²5,55,55,55,55,55,58,38,31/m²
Bulk density (±10 %)367320320320320320320320kg/m³
Thermal conductivity λ0,080,0710,0710,0710,0710,0710,0710,071W/(mK)
Thermal resistance, dry11,341,792,2433,734,485,37m²K/W
Thermal resistance at 50 % RH0,941,271,692,112,823,524,235,07m²K/W
sd value0,210,250,340,420,560,70,841m
Phase shift4,95,97,99,813,116,419,723,6h
Sound reduction Rw (simulated, plastered)3737383840414244dB
Fire resistance (plastered on one side)45456060120120240240min

For all thicknesses: diffusion resistance factor µ 2.8, compressive strength 0.2 MPa, sound absorption coefficient 0.85, reaction to fire B-s1,d0. From block 20 upwards, phase shift is practically negligible because of the high damping (over 300). Source: IsoHemp data sheet of 04.09.2026.

P and U blocks for the Hempro system

ValueP block 30P block 36U block 30U block 36Unit
Length x height600 x 200600 x 200600 x 300600 x 300mm
Maximum weight12,314,413,716,5kg
Recess15 x 1518 x 1815 x 4218 x 42cm
Recess cross-section225324630756cm²
Adhesive mortar consumption5,66,83,86,8kg/m²

Lintels for all wall openings

Prefabricated hempcrete lintels with a reinforced concrete core, 20 cm high. They are installed with the core on top and reduce thermal bridges.

Wall thickness (cm)120160200240300
max. opening80120160180240
934455668–
1237496173–
15527087104130
20577695114142
256182102122153
306789111133166

Columns: lintel length in cm. Rows: maximum weight in kg per wall thickness. A lintel is always chosen in the thickness of the adjoining wall.

Life cycle assessment

According to FDES INIES 20251046948 (EN 15804+A2, block 36, 50 years), the hemp stores around 62 kg CO₂ per m² of wall. The balance is −17.4 kg CO₂e/m² in production (A1–A3) and +58.9 kg CO₂e/m² over the life cycle (A–C).